When the data path must also be built.

OrigSmart can design the IoT solution from physical sensing to communication and data processing to business application.

OrigSmart hardware platform

Specific device families from the measurement point to the building gateway.

The product families are based on common data and device management logic, while power supply, communication and housing can be adapted to the specific installation location.

osgw2501

IoT Smart Gateway

Power supply
24 V DC according to system design
Installation
Modular DIN rail design
Environmental range
-20...+60 °C in industrial design
Data security
MQTT/TLS 1.2, local buffer

Building-level data gateway and automation center in DIN-rail, modular design. It connects sensors, meters and intervenors to the OrigSmart LEMP or external BMS system.

  • Ethernet and Wi‑Fi, configurable failover
  • Isolated RS485/Modbus, One‑Wire, I²C and SPI
  • LoRa 868 MHz, Zigbee 3.0 and BLE options
  • 16 digital I/O and 8 analog inputs
  • Local data buffer and isolated operation
MQTT/TLSREST APINode-REDDIN rail
osimb2501 / XL / ETH

M‑Bus Gateway family

Power supply
8-24V DC, optional PoE
Capacity
30 or 60 M-Bus endpoints
Environmental range
-20...+60 °C
Protection
IP20, optional IP65 housing

Reading the two-wire M-Bus network of consumption meters and connecting them to an IP-based energy management system.

  • EN 13757-2/3 M‑Bus master
  • Depending on the model, 30 or 60 endpoints
  • Primary and secondary addressing
  • Ethernet/PoE and Wi‑Fi variants
  • MQTT/JSON, raw telegram and Modbus TCP
Sub measurementWaterGasHeat
osirg2501-iso

Isolated RS485 gateway

Power supply
PoE 802.3af or 8-24 V DC
Disconnection
1500 Vrms, ±15 kV ESD protection
Environmental range
-20...+60 °C
EMC design basis
EN 61000-6-2 / EN 61000-6-4

For connecting industrial serial devices, meters, PLCs and inverters to an Ethernet or Wi‑Fi network.

  • Galvanically isolated RS485
  • Modbus RTU ↔ Modbus TCP
  • MQTT and REST integration
  • Ethernet/PoE and Wi-Fi
  • Transparent TCP/UDP mode
ModbusPoEIndustrial retrofit
osit2501 family

Temperature sensors

Measuring range
-55…+125 °C depending on the sensor
Accuracy
±0.5 °C in the typical operating range
Power supply
PoE, 8-24V DC or battery
Protection
IP40, optional IP65 housing

General, wall-mounted and pipe-mounted versions, with one- or two-channel measurement. For HVAC, boiler room and technology tasks.

  • Precision digital temperature measurement, in one- or two-channel design
  • Stainless steel sensor sleeve mounted on the barrel
  • Wired, Ethernet and LoRa versions
  • Battery and external powered versions
  • Configurable correction per channel
HVACLoRaBattery
osih2501 family

Temperature and humidity sensors

Temperature accuracy
±0.3 °C in the typical operating range
Humidity accuracy
±2% RH from 20 to 80% RH
Power supply
8-24V DC, PoE or battery
Protection
IP40, optional IP54 version

For comfort, warehouse, cellar, server room and institutional climate monitoring, with several types of communication.

  • Temperature, relative humidity and dew point
  • Wall and mounted designs
  • Ethernet/PoE, LoRa and wireless variants
  • MQTT/JSON transfer
  • LEMP and Home Assistant connectivity
ComfortAir conditioningWarehouse
osio2501 / LoRa

Opening sensor

Power supply
Battery or external power supply
Size
approx. 85 × 35 × 20 mm, depending on the version
Environmental range
-10...+55 °C
Protection
IP54 protected design

For event-driven monitoring of the status of doors, windows, gates, racks and control cabinets.

  • Open/closed detection with reed switch
  • LoRa, ESP‑NOW or Wi‑Fi communication
  • Battery operation and heartbeat
  • Low battery voltage indication
  • Alarm and event log integration
SecurityLoRaEvent

The listed interfaces and technical parameters depend on the model and configuration.

OrigSmart edge firmware

Common device lifecycle, not isolated microcodes.

Smart endpoints and on-premises gateways share common connection, configuration, and update patterns. This simplifies installation and subsequent support while not tying client-side operation to a specific controller chip.

DeviceSecure data connectionGateway / platformRemote operation
01

On-site commissioning

Wireless network configuration, device identification and persistent local settings.

02

Secure data connection

Structured data channels, status reporting, connection monitoring, automatic reconnection and remote commands.

03

Remote firmware update

Authenticated, versioned update; preliminary backup on the gateway side, operation check and, if necessary, restoration.

04

Permanent configuration

The settings are preserved even after a restart and a power failure, and can be managed remotely according to authorization.

05

Device status and diagnostics

Availability, software and hardware version, connection quality, uptime and operational status.

Integration technologies

Protocols for existing infrastructure.

Common libraries and target hardware projects in the firmware workspace cover the following technologies. Not all protocols are part of all devices; support is always determined by the specific model and firmware version.

MQTT / MQTTSModbus RTU/TCPM‑BusREST APIESP-NOWLoRa / LoRaWANSpark plug BOCPP 1.6-JSONGKNXNode-REDHome Assistant
Engineering services

From the idea to the working system in one hand.

We do not hand over separate tasks to each other. The physical environment, electronics, data connection and software are part of the same solution.

The common goalReliable measurement. Interpretable data. An operable system.
01
Exploration

IoT and system survey

Location, data sources, measurement objectives, environmental conditions and business expectations.

Output: feasibility picture and concept
02
Architecture

System and integration plan

Tools, interfaces, communication, data path, authorization and operating model.

Output: verifiable technical plan
03
Development

Electronics and mechanics

Custom PCB, application-specific assembly, cover, mounting and 3D model.

Output: manufacturable tool design
04
Validation

Prototype and field test

3D printing, 2.5D CNC, first copy, lab and field inspection.

Output: proven operation in a real environment
05
Introduction

Integration and commissioning

Platform connection, data verification, configuration, documentation and handover.

Output: usable, supported system
Technical consultation

The right tool starts with the specific measurement task.

The presented product families can be made with several types of communication, power supply and mechanical design. We help you choose the right configuration based on the location, the measurement purpose and the integration environment.

Next step

Request a technical consultation

Write what you want to measure, where the device would be installed, and what system it needs to connect to. Based on these, we provide a targeted technical proposal.

Getting in touch

Communication and scalability

The right technology is always a function of location, data rate, power supply, coverage and operational risk. The solution can use Wi-Fi, cellular, LoRaWAN or other industrial communication connections — only based on verified project requirements.

The goal is not to install another device, but to create reliable data for decision-making and processes.

Is there a measurement point for which there is no ready-made tool?

Engineering consultation